| * Copyright (c) 2013-2014 Nest Labs, Inc. |
| * All rights reserved. |
| * |
| * This document is the property of Nest. It is considered |
| * confidential and proprietary information. |
| * |
| * This document may not be reproduced or transmitted in any form, |
| * in whole or in part, without the express written permission of |
| * Nest. |
| * |
| */ |
| |
| /** |
| * @file |
| * This file defines Weave-specific constants used by the |
| * Nest Thermostat. |
| */ |
| |
| #ifndef WEAVE_PROFILES_NEST_THERMOSTAT_CONSTANTS |
| #define WEAVE_PROFILES_NEST_THERMOSTAT_CONSTANTS |
| |
| namespace nl { |
| |
| namespace Weave { |
| |
| namespace Profiles { |
| |
| namespace Vendor { |
| |
| namespace Nestlabs { |
| |
| namespace Thermostat { |
| |
| // Thermostat-specific status codes |
| |
| typedef enum |
| { |
| kStatus_InFieldJoining_Unknown = -1, // Unknown |
| kStatus_InFieldJoining_Null = 0, // In-field joining started by the service |
| kStatus_InFieldJoining_Succeeded = 1, // In-field joining succeeded |
| kStatus_InFieldJoining_CannotLocateAssistingDevice = 2, // Failure to locate assisting device |
| kStatus_InFieldJoining_CannotConnectAssistingDevice = 3, // Failure to connect to assisting device |
| kStatus_InFieldJoining_CannotAuthAssistingDevice = 4, // Failure to authenticate to assisting device |
| kStatus_InFieldJoining_ConfigExtractionError = 5, // Error extracting configuration from assisting device |
| kStatus_InFieldJoining_PANFormError = 6, // Failure to form 802.15.4 PAN |
| kStatus_InFieldJoining_PANJoinError = 7, // Failure to join 802.15.4 PAN |
| kStatus_InFieldJoining_HVACCycleInProgress = 8, // HVAC cycle in progress |
| kStatus_InFieldJoining_HeatLinkJoinInProgress = 9, // HeatLink join in progress |
| kStatus_InFieldJoining_HeatLinkUpdateInProgress = 10, // HeatLink software update in progress |
| kStatus_InFieldJoining_HeatLinkManualHeatActive = 11, // Heatlink manual heat active |
| kStatus_InFieldJoining_IncorrectHeatLinkSoftwareVersion = 12, // Incorrect HeatLink software version |
| kStatus_InFieldJoining_FailureToFetchAccessToken = 13, // Failure to fetch access token |
| kStatus_InFieldJoining_DeviceNotWeaveProvisioned = 14, // Device not Weave provisioned |
| kStatus_InFieldJoining_HeatLinkResetFailed = 15, // Failed to factory reset HeatLink |
| kStatus_InFieldJoining_DestroyFabricFailed = 16, // Failed to destroy existing fabric |
| kStatus_InFieldJoining_CannotJoinExistingFabric = 17, // Failed to join existing fabric |
| kStatus_InFieldJoining_CannotCreateFabric = 18, // Failed to create new fabric |
| kStatus_InFieldJoining_NetworkReset = 19, // Network was reset on the device |
| kStatus_InFieldJoining_JoiningInProgress = 20, // Device already in-field joining |
| kStatus_InFieldJoining_FailureToMakePanJoinable = 21, // Assisting device failed to make it's PAN joinable |
| kStatus_InFieldJoining_WeaveConnectionTimeoutStillActive = 22, // Timeout used to keep us awake while connected to another device still active |
| kStatus_InFieldJoining_HeatLinkNotJoined = 23, // HeatLink not joined to head unit |
| kStatus_InFieldJoining_HeatLinkNotInContact = 24, // HeatLink not in contact with head unit |
| kStatus_InFieldJoining_WiFiTechNotEnabled = 25, // WiFi technology is not enabled |
| kStatus_InFieldJoining_15_4_TechNotEnabled = 26, // 15.4 technology is not enabled |
| kStatus_InFieldJoining_StandaloneFabricCreationInProgress = 27, // Standalone fabric creation is in progress |
| kStatus_InFieldJoining_NotConnectedToPower = 28, // Backplate not connected to any power |
| kStatus_InFieldJoining_OperationNotPermitted = 29, // In-field joining not permitted |
| kStatus_InFieldJoining_ServiceTimedOut = 100, // Joining operation timed out (set by service) |
| kStatus_InFieldJoining_DeviceTimedOut = 101, // Joining operation timed out (set by device) |
| kStatus_InFieldJoining_InternalError = 200, // Internal error during in-field joining |
| |
| kStatus_InFieldJoining_MinComplete = kStatus_InFieldJoining_Succeeded, |
| kStatus_InFieldJoining_MaxComplete = kStatus_InFieldJoining_InternalError, |
| } InFieldJoiningStatus; |
| |
| #define IFJ_STATUS_COMPLETE(_result) (((_result) >= kStatus_InFieldJoining_MinComplete) && ((_result) <= kStatus_InFieldJoining_MaxComplete)) |
| |
| const char *IfjStatusStr(InFieldJoiningStatus status); |
| |
| // Thermostat-specific tags |
| // |
| // Tag Tag Element |
| // Number Category Type Constraints Disposition Readability Writability |
| // ----------------------------------------------------------------------------------------------- |
| |
| enum { |
| kTag_LegacyEntryKey = 0x0001, // Profile-specific UTF-8 String None Optional Any - |
| kTag_SystemTestStatusKey = 0x0002, // Profile-specific Unsigned Int See tbl 4 Optional Any - |
| }; |
| |
| // Thermostat-specific status codes |
| enum { |
| kStatus_ServiceUnreachable = 0x0001, // Cannot contact the Service to retrieve the Legacy Entry Key |
| kStatus_DeviceAlreadyPaired = 0x0002, // The device is already paired to a Nest account |
| }; |
| |
| // Thermostat-specific system test codes. Do not change these values even if a test gets deprecated. |
| // They are used in kTag_SystemTestStartKey Update requests and kTag_SystemTestStatusKey view responses |
| typedef enum { |
| kSystemTestCode_None = 0x00, |
| kSystemTestCode_Cooling = 0x01, |
| kSystemTestCode_Heating = 0x02, |
| kSystemTestCode_AlternateHeating = 0x03, |
| kSystemTestCode_AuxiliaryHeating = 0x04, |
| kSystemTestCode_Dehumidifier = 0x05, |
| kSystemTestCode_EmergencyHeating = 0x06, |
| kSystemTestCode_Fan = 0x07, |
| kSystemTestCode_Humidifier = 0x08, |
| kSystemTestCode_AlternateHeatStage2 = 0x09, |
| kSystemTestCode_CoolingStage2 = 0x0A, |
| kSystemTestCode_HeatingStage2 = 0x0B, |
| kSystemTestCode_HeatingStage3 = 0x0C, |
| } SystemTestCode; |
| |
| |
| // Thermostat-specific system test status codes. Do not change these values even if a test status gets deprecated. |
| // They are used in kTag_SystemTestStatusKey view responses. The lower byte of these values will be used to store |
| // specific test codes from the SystemTestCode enum above. |
| typedef enum { |
| kSystemTestStatusCode_Idle = 0x0000, |
| kSystemTestStatusCode_Running = 0x0100, |
| kSystemTestStatusCode_Timeout = 0x0200, |
| kSystemTestStatusCode_TooHot = 0x0300, |
| kSystemTestStatusCode_TooCold = 0x0400, |
| kSystemTestStatusCode_CompressorLockout = 0x0500, |
| kSystemTestStatusCode_Invalid = 0x0600, |
| kSystemTestStatusCode_WeatherRequired = 0x0700, |
| } SystemTestStatusCode; |
| |
| // Thermostat-specific system status codes. Do not change these values even if a status gets deprecated. |
| // They are used in kTag_SystemStatusKey view responses |
| typedef enum { |
| kSystemStatusCode_Idle = 0x0000, //No error codes or special conditions |
| kSystemStatusCode_NoWeatherInfo = 0x0001, //No weather info, system tests not possible |
| kSystemStatusCode_MandatoryUpdateUnknown = 0x0002, //Still checking if a mandatory update is needed |
| kSystemStatusCode_MandatoryUpdateInProgress = 0x0004, //Mandatory update in progress |
| } SystemStatusCode; |
| |
| }; // namespace Thermostat |
| |
| }; // namespace Nestlabs |
| |
| }; // namespace Vendor |
| |
| }; // namespace Profiles |
| |
| }; // namespace Weave |
| |
| }; // namespace nl |
| |
| #endif // WEAVE_PROFILES_NEST_THERMOSTAT_CONSTANTS |