blob: af7c106f6b4889bcfc0f568780cd7a6dfdff3193 [file] [log] [blame]
/*******************************************************************************
* (c) Copyright 2008-2013 Microsemi SoC Products Group. All rights reserved.
*
* SmartFusion2 MSS RTC bare metal software driver public API.
*
* SVN $Revision: 5396 $
* SVN $Date: 2013-03-27 21:57:50 +0000 (Wed, 27 Mar 2013) $
*/
/*=========================================================================*//**
@mainpage SmartFusion2 MSS RTC Bare Metal Driver.
@section intro_sec Introduction
The SmartFusion2 microcontroller subsystem (MSS) includes a real time counter
(RTC) that can generate alarms and wakeup interrupts in real time. This
software driver provides a set of functions for controlling the MSS RTC as
part of a bare metal system where no operating system is available. The driver
can be adapted for use as part of an operating system, but the implementation
of the adaptation layer between the driver and the operating system's driver
model is outside the scope of the driver.
The MSS RTC driver provides support for the following features:
- Initialization of the RTC
- Configuration of the RTC timebase
- Configuration as a calendar or binary mode counter
- Set the current calendar or binary mode count
- Get the current calendar or binary mode count
- Start and stop the RTC counting
- Set alarm conditions
- Enable, disable and clear the wakeup interrupt
@section hw_dependencies Hardware Flow Dependencies
The configuration of all features of the MSS RTC is covered by this driver
with the exception of the clock source driving the MSS RTC clock (RTCCLK)
input. The SmartFusion2 MSS clock controller can supply one of three clock
sources to the MSS RTC clock input:
- Crystal Oscillator 32.768 kHz
- 1MHz Oscillator
- 50MHz Oscillator. (25 MHz in a 1.0v part).
The SmartFusion2 MSS configurator tool in the hardware flow configures one
of these clocks as the RTCCLK input source.
The base address and register addresses and interrupt number assignment for
the MSS RTC block are defined as constants in the SmartFusion2 CMSIS HAL. You
must ensure that the SmartFusion2 CMSIS HAL is either included in the software
tool chain used to build your project or is included in your project.
@section theory_op Theory of Operation
The MSS RTC driver functions are grouped into the following categories:
- Initialization of the RTC driver and hardware
- Setting and reading the RTC counter current value
- Setting RTC alarm values
- Starting and stopping the RTC
- Interrupt Control
Initialization
The MSS RTC driver is initialized through a call to the MSS_RTC_init()
function. The MSS_RTC_init() function must be called before any other MSS RTC
driver functions are called.
The MSS_RTC_init() function:
- Stops the RTC counters and disables the RTC alarm
- Disables the RTC wakeup interrupt in the RTC and in the Cortex-M3
interrupt controller (NVIC).
- Clears any pending RTC wakeup interrupt in the RTC and in the Cortex-M3
interrupt controller (NVIC).
- Enables the RTC_WAKEUP_CR[0] mask bit in the MSS System Register to
connect the RTC wakeup interrupt to the Cortex-M3 interrupt controller.
- Resets the RTC counters and the alarm and compare registers
- Sets the RTC's operating mode to binary counter mode or calendar counter
mode, as specified by the mode parameter
- Sets the RTC's prescaler register to the value specified by the prescaler
parameter. The frequency of the clock source driving the MSS RTC clock
(RTCCLK) input is required to calculate the prescaler value.
Setting and Reading the RTC Counter Value
The MSS RTC supports two mode of operation – binary mode and calendar mode.
The following functions are used to set and read the current value of the
counter when the MSS RTC is configured to operate in binary mode:
- MSS_RTC_set_binary_count() – This function is used to set the current
value of the RTC binary counter.
- MSS_RTC_get_binary_count() – This function is used to read the current
value of the RTC binary counter.
The following functions are used to set and read the current value of the
counter the MSS RTC is configured to operate in calendar mode:
- MSS_RTC_set_calendar_count() – This function is used to set the current
value of the RTC calendar counter.
- MSS_RTC_get_calendar_count() – This function is used to read the current
value of the RTC calendar counter.
The following functions resets the RTC counter in either binary and calendar
operating mode:
- MSS_RTC_reset_counter() – This function resets the RTC counter.
Setting RTC Alarms
The MSS RTC can generate alarms when the counter matches a specified count
value in binary mode or a date and time in calendar mode.
The following functions are used to set up alarms:
- MSS_RTC_set_binary_count_alarm() – This function sets up one-shot or
periodic alarms when the MSS RTC is configured to operate in binary mode.
- MSS_RTC_set_calendar_count_alarm() – This function sets up one-shot or
periodic alarms when the MSS RTC is configured to operate in calendar
mode.
Note: The alarm asserts a wakeup interrupt to the Cortex-M3. This function
enables the RTC’s wakeup interrupt output, however the RTC wakeup
interrupt input to the Cortex-M3 NVIC must be enabled separately by
calling the MSS_RTC_enable_irq() function. The alarm can be disabled at
any time by calling the MSS_RTC_disable_irq() function. activate
Starting and Stopping the RTC Counter
The following functions start and stop the RTC counter:
- MSS_RTC_start() – This function starts the RTC counter.
- MSS_RTC_stop() – This function stops the RTC counter.
Interrupt Control
The MSS_RTC_init() function enables the RTC_WAKEUP_CR[0] mask bit in the MSS
System Register to connect the RTC wakeup interrupt to the Cortex-M3 interrupt
controller.
An RTC_Wakeup_IRQHandler() default implementation is defined, with weak
linkage, in the SmartFusion2 CMSIS HAL. You must provide your own
implementation of the RTC_Wakeup_IRQHandler() function, which will override
the default implementation, to suit your application.
The function prototype for the RTC wakeup interrupt handler is as follows:
void RTC_Wakeup_IRQHandler ( void )
The RTC wakeup interrupt is controlled using the following functions:
- MSS_RTC_enable_irq() – The MSS_RTC_enable_irq() function enables the RTC
to interrupt the Cortex-M3 when a wakeup alarm occurs.
- MSS_RTC_disable_irq() – The MSS_RTC_disable_irq() function disables the
RTC from interrupting the Cortex-M3 when a wakeup alarm occurs.
- MSS_RTC_clear_irq() – The MSS_RTC_clear_irq() function clears a pending
RTC wakeup interrupt at the RTC wakeup output. You must call the
MSS_RTC_clear_irq() function as part of your implementation of the
RTC_Wakeup_IRQHandler() interrupt service routine (ISR) in order to
prevent the same interrupt event retriggering a call to the ISR.
*//*=========================================================================*/
#ifndef MSS_RTC_H_
#define MSS_RTC_H_
#ifdef __cplusplus
extern "C" {
#endif
#include "../../CMSIS/m2sxxx.h"
/*-------------------------------------------------------------------------*//**
The MSS_RTC_BINARY_MODE constant is used to specify the mode parameter to the
MSS_RTC_init() function. The RTC will run in binary mode if this constant is
used. In binary mode, the calendar counter counts consecutively from 0 all the
way to 2^43.
*/
#define MSS_RTC_BINARY_MODE 0u
/*-------------------------------------------------------------------------*//**
The MSS_RTC_CALENDAR_MODE constant is used to specify the mode parameter to
the MSS_RTC_init() function. The RTC will run in calendar mode if this
constant is used. In calendar mode, the calendar counter counts seconds,
minutes, hours, days, months, years, weekdays and weeks.
*/
#define MSS_RTC_CALENDAR_MODE 1u
/*-------------------------------------------------------------------------*//**
The alarm_value parameter of the MSS_RTC_set_calendar_count_alarm() function
is a pointer to an mss_rtc_calendar_t data structure specifying the date and
time at which the alarm is to occur. You must assign the required date and
time values to the mss_rtc_calendar_t structure before calling the function.
Any of the fields of the mss_rtc_calendar_t structure can be set to
MSS_RTC_CALENDAR_DONT_CARE, to indicate that they are not to be considered in
deciding when the alarm will occur; this is necessary when setting periodic
alarms.
*/
#define MSS_RTC_CALENDAR_DONT_CARE 0xFFu
/*-------------------------------------------------------------------------*//**
Days of the week.
*/
#define MSS_RTC_SUNDAY 1u
#define MSS_RTC_MONDAY 2u
#define MSS_RTC_TUESDAY 3u
#define MSS_RTC_WEDNESDAY 4u
#define MSS_RTC_THRUSDAY 5u
#define MSS_RTC_FRIDAY 6u
#define MSS_RTC_SATURDAY 7u
/*-------------------------------------------------------------------------*//**
The mss_rtc_alarm_type_t enumeration is used as the alarm_type parameter for
the MSS_RTC_set_calendar_count_alarm() and MSS_RTC_set_binary_count_alarm()
functions to specify whether the requested alarm should occur only one time or
periodically.
*/
typedef enum {
MSS_RTC_SINGLE_SHOT_ALARM,
MSS_RTC_PERIODIC_ALARM
} mss_rtc_alarm_type_t;
/*-------------------------------------------------------------------------*//**
A pointer to an instance of the mss_rtc_calender_t data structure is used to
write new date and time values to the RTC using the
MSS_RTC_set_rtc_calendar_count() and MSS_RTC_set_calendar_count_alarm()
functions. The MSS_RTC_get_calendar_count() function also uses a pointer to an
instance of the mss_rtc_calender_t data structure to read the current date and
time value from the RTC.
*/
typedef struct mss_rtc_calendar
{
uint8_t second;
uint8_t minute;
uint8_t hour;
uint8_t day;
uint8_t month;
uint8_t year;
uint8_t weekday;
uint8_t week;
} mss_rtc_calendar_t ;
/*-------------------------------------------------------------------------*//**
The MSS_RTC_init() function initializes the RTC driver and hardware to a known
state.
To initialize the RTC hardware, this function:
- Stops the RTC counters and disables the RTC alarm
- Disables the RTC wakeup interrupt in the RTC and in the Cortex-M3
interrupt controller (NVIC).
- Clears any pending RTC wakeup interrupt in the RTC and in the Cortex-M3
interrupt controller (NVIC).
- Resets the RTC counters and the alarm and compare registers
- Sets the RTC's operating mode to binary counter mode or calendar counter
mode, as specified by the mode parameter
- Sets the RTC's prescaler register to the value specified by the prescaler
parameter
The MSS clock controller can supply one of three clock sources to the RTC
clock input (RTCCLK):
- Crystal Oscillator 32.768 kHz
- 1MHz Oscillator
- 50MHz Oscillator. (25 MHz in a 1.0v part).
For calendar mode, program the prescaler register to generate a 1Hz signal
from the active RTCCLK according to the following equation:
prescaler = RTCCLK – 1 (where RTCCLK unit is Hz)
For a 32.768 kHz clock, set the prescaler to 32768 - 1 = 32767. The prescaler
register is 26 bits wide, allowing clock sources of up to 67 MHz to generate
the 1Hz time base.
For binary mode, the prescaler register can be programmed to generate a 1Hz
time base or a different time base, as required.
@param mode
The mode parameter is used to specify the operating mode of the RTC. The
allowed values for mode are:
- MSS_RTC_BINARY_MODE
- MSS_RTC_CALENDAR_MODE
@param prescaler
The prescaler parameter specifies the value to divide the incoming RTC clock
by, to generate the RTC time base signal. For calendar mode, set the
prescaler value to generate a 1Hz time base from the incoming RTC clock
according to the following equation:
prescaler = RTCCLK – 1 (where the RTCCLK unit is Hz)
For binary mode, set the prescaler value to generate a 1Hz time base or a
different time base, as required.
The prescaler parameter can be any integer value in the range 2 to 2^26.
@return
This function does not return a value.
The example code below shows how the RTC can be initialized only after a power-on
reset.
@code
#define PO_RESET_DETECT_MASK 0x00000001u
void init_application(void)
{
uint32_t power_on_reset;
power_on_reset = SYSREG->RESET_SOURCE_CR & PO_RESET_DETECT_MASK;
if(power_on_reset)
{
MSS_RTC_init(MSS_RTC_CALENDAR_MODE, 32767);
SYSREG->RESET_SOURCE_CR = PO_RESET_DETECT_MASK;
}
}
@endcode
*/
void
MSS_RTC_init
(
uint8_t mode,
uint32_t prescaler
);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_set_rtc_calendar_count() function sets the current value of the
RTC calendar counter.
Note: This function must only be used when the RTC is configured to operate in
calendar counter mode.
@param new_rtc_value
The new_rtc_value parameter is a pointer to an mss_rtc_calendar_t data
structure specifying the new date and time value from which the RTC will
increment. You must populate the mss_rtc_calendar_t structure with the
required date and time values before calling this function.
@return
This function does not return a value.
*/
void
MSS_RTC_set_calendar_count
(
const mss_rtc_calendar_t *new_rtc_value
);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_set_binary_count() function sets the current value of the RTC
binary counter.
Note: This function must only be used when the RTC is configured to operate in
binary counter mode.
@param new_rtc_value
The new_rtc_value parameter specifies the new count value from which the RTC
will increment. The binary counter is 43 bits wide, so the maximum allowed
binary value is 2^43.
@return
This function does not return a value.
*/
void
MSS_RTC_set_binary_count
(
uint64_t new_rtc_value
);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_get_calendar_count() function returns the current value of the RTC
calendar counter via the data structure pointed to by the p_rtc_calendar
parameter.
Note: This function must only be used when the RTC is configured to operate in
calendar counter mode.
@param p_rtc_calendar
The p_rtc_calendar parameter is a pointer to an mss_rtc_calendar_t data
structure where the current value of the calendar counter will be written by
the MSS_RTC_get_calendar_count() function
@return
This function does not return a value.
*/
void
MSS_RTC_get_calendar_count
(
mss_rtc_calendar_t *p_rtc_calendar
);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_get_binary_count() function returns the current value of the RTC
binary counter.
Note: This function must only be used when the RTC is configured to operate in
binary counter mode.
@param
This function takes no parameters.
@return
This function returns the current value of the RTC binary counter as an
unsigned 64-bit integer.
*/
uint64_t
MSS_RTC_get_binary_count(void);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_start() function starts the RTC incrementing.
@param
This function takes no parameters.
@return
This function does not return a value.
*/
void MSS_RTC_start(void);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_stop() function stops the RTC from incrementing.
@param
This function takes no parameters.
@return
This function does not return a value.
*/
void MSS_RTC_stop(void);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_reset_counter() function resets the RTC counters. If the counter
was running before calling this function, then it continues incrementing from
the counter’s reset value.
@param
This function takes no parameters.
@return
This function does not return a value.
*/
void MSS_RTC_reset_counter(void);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_enable_irq() function enables the RTC wakeup output to interrupt
the Cortex-M3 when an alarm occurs. It enables the RTC wakeup interrupt
(RTC_Wakeup_IRQn) in the Cortex-M3 interrupt controller (NVIC). The
RTC_Wakeup_IRQHandler() function will be called when an RTC wakeup interrupt
occurs.
Note: An RTC_Wakeup_IRQHandler() default implementation is defined, with weak
linkage, in the SmartFusion2 CMSIS HAL. You must provide your own
implementation of the RTC_Wakeup_IRQHandler() function, which will
override the default implementation, to suit your application.
Note: This function only enables the RTC wakeup interrupt at the Cortex-M3
NVIC level. The alarm setting functions enable the wakeup interrupt
output from the RTC.
*/
void MSS_RTC_enable_irq(void);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_disable_irq() function disables the RTC wakeup interrupt
(RTC_Wakeup_IRQn) in the Cortex-M3 interrupt controller (NVIC).
Note: This function only disables the RTC wakeup interrupt at the Cortex-M3
NVIC level. It does not disable the wakeup interrupt output from the
RTC.
@param
This function takes no parameters.
@return
This function does not return a value.
*/
void MSS_RTC_disable_irq(void);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_clear_irq() function clears a pending wakeup interrupt from the
RTC. This function does not clear the interrupt in the Cortex-M3 interrupt
controller (NVIC); it only clears the wakeup output from the RTC.
Note: You must call the MSS_RTC_clear_irq() function as part of your
implementation of the RTC_Wakeup_IRQHandler() RTC wakeup interrupt
service routine (ISR) in order to prevent the same interrupt event
retriggering a call to the ISR.
@param
This function takes no parameters.
@return
This function does not return a value.
Example:
The example code below demoinstrates how the MSS_RTC_clear_irq() function is
intended to be used as part of the RTC wakeup interrupt servicer routine used
by an application to handle RTC alarms.
@code
#if defined(__GNUC__)
__attribute__((__interrupt__)) void RTC_Wakeup_IRQHandler( void )
#else
void RTC_Wakeup_IRQHandler( void )
#endif
{
process_alarm();
MSS_RTC_clear_irq();
}
@endcode
*/
void MSS_RTC_clear_irq(void);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_set_calendar_count_alarm() function sets up the RTC to generate an
alarm when the RTC count reaches the time/date specified by the alarm_value
parameter. The alarm asserts a wakeup interrupt to the Cortex-M3. This
function enables the RTC’s wakeup interrupt output, however the RTC wakeup
interrupt input to the Cortex-M3 NVIC must be enabled separately by calling
the MSS_RTC_enable_irq() function. The alarm can be disabled at any time by
calling the MSS_RTC_disable_irq() function.
Single-shot alarm
The alarm can be a single-shot alarm, which will generate a single wakeup
interrupt the first time the RTC count reaches the time/date specified by
alarm_value. A single shot alarm is achieved by specifying a value for every
field of the mss_rtc_calendar_t data structure pointed to by the alarm_value
parameter. The RTC counter will keep incrementing after a single shot alarm
occurs.
Periodic alarm
The alarm can also be a periodic alarm, which will generate a wakeup interrupt
every time the RTC count reaches the time/date specified by alarm_value, with
the counter running in a continuous loop. The periodic alarm can be set to
occur every minute, hour, day, month, year, week, day of the week, or any
valid combination of these. This is achieved by setting some of the fields of
the mss_rtc_calendar_t data structure pointed to by the alarm_value parameter,
to MSS_RTC_CALENDAR_DONT_CARE. For example, setting the weekday field to
MSS_RTC_MONDAY and all other fields to MSS_RTC_CALENDAR_DONT_CARE will result
in an alarm occurring every Monday. You can refine the time at which the alarm
will occur by specifying values for the hour, minute and second fields.
Note: This function must only be used when the RTC is configured to operate in
calendar counter mode.
@param alarm_value
The alarm_value parameter is a pointer to an mss_rtc_calendar_t data
structure specifying the date and time at which the alarm is to occur. You
must assign the required date and time values to the mss_rtc_calendar_t
structure before calling this function. Some of the fields within the
mss_rtc_calendar_t structure can be set to MSS_RTC_CALENDAR_DONT_CARE, to
indicate that they are not to be considered in deciding when the alarm will
occur; this is necessary when setting periodic alarms.
@return
This function does not return a value.
Examples:
The following example code demonstrates how to configure the RTC to generate a
single calendar alarm at a specific date and time. The alarm will only occur
once and the RTC will keep incrementing regardless of the alarm taking place.
@code
const mss_rtc_calendar_t initial_calendar_count =
{
15u, second
30u, minute
6u, hour
6u, day
9u, month
12u, year
5u, weekday
37u week
};
mss_rtc_calendar_t alarm_calendar_count =
{
17u, second
30u, minute
6u, hour
6u, day
9u, month
12u, year
5u, weekday
37u week
};
MSS_RTC_init(MSS_RTC_CALENDAR_MODE, RTC_PRESCALER);
MSS_RTC_clear_irq();
MSS_RTC_set_calendar_count(&initial_calendar_count);
MSS_RTC_enable_irq();
MSS_RTC_start();
MSS_RTC_set_calendar_count_alarm(&alarm_calendar_count);
@endcode
The following example code demonstrates how to configure the RTC to generate a
periodic calendar alarm. The RTC is configured to generate an alarm every
Tuesday at 16:45:00. The alarm will reoccur every week until the RTC wakeup
interrupt is disabled using a call to MSS_RTC_disable_irq().
@code
mss_rtc_calendar_t initial_calendar_count =
{
58u, <--second
59u, <--minute
23u, <--hour
10u, <--day
9u, <--month
12u, <--year
MSS_RTC_MONDAY, <--weekday
37u <--week
};
mss_rtc_calendar_t alarm_calendar_count =
{
MSS_RTC_CALENDAR_DONT_CARE, <--second
45u, <--minute
16u, <--hour
MSS_RTC_CALENDAR_DONT_CARE, <--day
MSS_RTC_CALENDAR_DONT_CARE, <--month
MSS_RTC_CALENDAR_DONT_CARE, <--year
MSS_RTC_TUESDAY, <--weekday
MSS_RTC_CALENDAR_DONT_CARE <--week
};
MSS_RTC_init(MSS_RTC_CALENDAR_MODE, RTC_PRESCALER);
MSS_RTC_set_calendar_count(&initial_calendar_count);
MSS_RTC_enable_irq();
MSS_RTC_start();
MSS_RTC_set_calendar_count_alarm(&alarm_calendar_count);
@endcode
The following example code demonstrates the code that you need to include in
your application to handle alarms. It is the interrupt service routine for the
RTC wakeup interrupt input to the Cortex-M3 NVIC. You need to add your
application code in this function in place of the process_alarm() function but
you must retain the call to MSS_RTC_clear_irq() to ensure that the same alarm
does not retrigger the interrupt.
@code
#if defined(__GNUC__)
__attribute__((__interrupt__)) void RTC_Wakeup_IRQHandler( void )
#else
void RTC_Wakeup_IRQHandler( void )
#endif
{
process_alarm();
MSS_RTC_clear_irq();
}
@endcode
*/
void MSS_RTC_set_calendar_count_alarm
(
const mss_rtc_calendar_t * alarm_value
);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_set_binary_count_alarm() function sets up the RTC to generate an
alarm when the RTC count reaches the value specified by the alarm_value
parameter. The alarm asserts a wakeup interrupt to the Cortex-M3. This
function enables the RTC’s wakeup interrupt output, however the RTC wakeup
interrupt input to the Cortex-M3 NVIC must be enabled separately by calling
the MSS_RTC_enable_irq() function. The alarm can be disabled at any time by
calling the MSS_RTC_disable_irq() function.
Single-shot alarm
The alarm can be a single-shot alarm, which will generate a single wakeup
interrupt the first time the RTC count reaches the value specified by the
alarm_value parameter. Setting the alarm_value parameter to
MSS_RTC_PERIODIC_ALARM produces a single-shot alarm. The RTC counter continues
incrementing when a single shot alarm occurs.
Periodic alarm
The alarm can also be a periodic alarm, which will generate a wakeup interrupt
every time the RTC count reaches the value specified by the alarm_value
parameter. Setting the alarm_value parameter to MSS_RTC_SINGLE_SHOT_ALARM
produces a periodic alarm. The RTC counter automatically wraps around to zero
and continues incrementing when a periodic alarm occurs.
Note: This function must only be used when the RTC is configured to operate in
binary counter mode
@param alarm_value
The alarm_value parameter is a 64-bit unsigned value specifying the RTC
counter value that must be reached for the requested alarm to occur.
@param alarm_type
The alarm_type parameter specifies whether the requested alarm is a single
shot or periodic alarm. It can only take one of these two values:
- MSS_RTC_SINGLE_SHOT_ALARM,
- MSS_RTC_PERIODIC_ALARM
@return
This function does not return a value.
*/
void MSS_RTC_set_binary_count_alarm
(
uint64_t alarm_value,
mss_rtc_alarm_type_t alarm_type
);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_get_update_flag() function indicates if the RTC counter has
incremented since the last call to MSS_RTC_clear_update_flag(). It returns
zero if no RTC counter increment has occurred. It returns a non-zero value if
the RTC counter has incremented. This function can be used whether the RTC is
configured to operate in calendar or binary counter mode.
@return
This function returns,
zero: if the RTC has not incremented since the last call to
MSS_RTC_clear_update_flag(),
non-zero: if the RTC has incremented since the last call to
MSS_RTC_clear_update_flag().
Example
This example waits for the RTC timer to increment by one second.
@code
void wait_start_of_second(void)
{
uint32_t rtc_count_updated;
MSS_RTC_clear_update_flag();
do {
rtc_count_updated = MSS_RTC_get_update_flag();
} while(!rtc_count_updated)
}
@endcode
*/
uint32_t MSS_RTC_get_update_flag(void);
/*-------------------------------------------------------------------------*//**
The MSS_RTC_clear_update_flag() function clears the CONTROL register flag that
is set when the RTC counter increments. It is used alongside function
MSS_RTC_get_update_flag() to detect RTC counter increments.
@return
This function does not return a value.
Example
The example below will wait for the RTC timer to increment by one second.
@code
void wait_start_of_second(void)
{
uint32_t rtc_count_updated;
MSS_RTC_clear_update_flag();
do {
rtc_count_updated = MSS_RTC_get_update_flag();
} while(!rtc_count_updated)
}
@endcode
*/
void MSS_RTC_clear_update_flag(void);
#ifdef __cplusplus
}
#endif