| # | |
| # Network device configuration | |
| # | |
| menuconfig NETDEVICES | |
| default y if UML | |
| depends on NET | |
| bool "Network device support" | |
| ---help--- | |
| You can say N here if you don't intend to connect your Linux box to | |
| any other computer at all. | |
| You'll have to say Y if your computer contains a network card that | |
| you want to use under Linux. If you are going to run SLIP or PPP over | |
| telephone line or null modem cable you need say Y here. Connecting | |
| two machines with parallel ports using PLIP needs this, as well as | |
| AX.25/KISS for sending Internet traffic over amateur radio links. | |
| See also "The Linux Network Administrator's Guide" by Olaf Kirch and | |
| Terry Dawson. Available at <http://www.tldp.org/guides.html>. | |
| If unsure, say Y. | |
| # All the following symbols are dependent on NETDEVICES - do not repeat | |
| # that for each of the symbols. | |
| if NETDEVICES | |
| config NET_CORE | |
| default y | |
| bool "Network core driver support" | |
| ---help--- | |
| You can say N here if you do not intend to use any of the | |
| networking core drivers (i.e. VLAN, bridging, bonding, etc.) | |
| if NET_CORE | |
| config BONDING | |
| tristate "Bonding driver support" | |
| depends on INET | |
| depends on IPV6 || IPV6=n | |
| ---help--- | |
| Say 'Y' or 'M' if you wish to be able to 'bond' multiple Ethernet | |
| Channels together. This is called 'Etherchannel' by Cisco, | |
| 'Trunking' by Sun, 802.3ad by the IEEE, and 'Bonding' in Linux. | |
| The driver supports multiple bonding modes to allow for both high | |
| performance and high availability operation. | |
| Refer to <file:Documentation/networking/bonding.txt> for more | |
| information. | |
| To compile this driver as a module, choose M here: the module | |
| will be called bonding. | |
| config DUMMY | |
| tristate "Dummy net driver support" | |
| ---help--- | |
| This is essentially a bit-bucket device (i.e. traffic you send to | |
| this device is consigned into oblivion) with a configurable IP | |
| address. It is most commonly used in order to make your currently | |
| inactive SLIP address seem like a real address for local programs. | |
| If you use SLIP or PPP, you might want to say Y here. Since this | |
| thing often comes in handy, the default is Y. It won't enlarge your | |
| kernel either. What a deal. Read about it in the Network | |
| Administrator's Guide, available from | |
| <http://www.tldp.org/docs.html#guide>. | |
| To compile this driver as a module, choose M here: the module | |
| will be called dummy. | |
| config EQUALIZER | |
| tristate "EQL (serial line load balancing) support" | |
| ---help--- | |
| If you have two serial connections to some other computer (this | |
| usually requires two modems and two telephone lines) and you use | |
| SLIP (the protocol for sending Internet traffic over telephone | |
| lines) or PPP (a better SLIP) on them, you can make them behave like | |
| one double speed connection using this driver. Naturally, this has | |
| to be supported at the other end as well, either with a similar EQL | |
| Linux driver or with a Livingston Portmaster 2e. | |
| Say Y if you want this and read | |
| <file:Documentation/networking/eql.txt>. You may also want to read | |
| section 6.2 of the NET-3-HOWTO, available from | |
| <http://www.tldp.org/docs.html#howto>. | |
| To compile this driver as a module, choose M here: the module | |
| will be called eql. If unsure, say N. | |
| config NET_FC | |
| bool "Fibre Channel driver support" | |
| depends on SCSI && PCI | |
| help | |
| Fibre Channel is a high speed serial protocol mainly used to connect | |
| large storage devices to the computer; it is compatible with and | |
| intended to replace SCSI. | |
| If you intend to use Fibre Channel, you need to have a Fibre channel | |
| adaptor card in your computer; say Y here and to the driver for your | |
| adaptor below. You also should have said Y to "SCSI support" and | |
| "SCSI generic support". | |
| config MII | |
| tristate "Generic Media Independent Interface device support" | |
| help | |
| Most ethernet controllers have MII transceiver either as an external | |
| or internal device. It is safe to say Y or M here even if your | |
| ethernet card lacks MII. | |
| config IFB | |
| tristate "Intermediate Functional Block support" | |
| depends on NET_CLS_ACT | |
| ---help--- | |
| This is an intermediate driver that allows sharing of | |
| resources. | |
| To compile this driver as a module, choose M here: the module | |
| will be called ifb. If you want to use more than one ifb | |
| device at a time, you need to compile this driver as a module. | |
| Instead of 'ifb', the devices will then be called 'ifb0', | |
| 'ifb1' etc. | |
| Look at the iproute2 documentation directory for usage etc | |
| source "drivers/net/team/Kconfig" | |
| config MACVLAN | |
| tristate "MAC-VLAN support" | |
| ---help--- | |
| This allows one to create virtual interfaces that map packets to | |
| or from specific MAC addresses to a particular interface. | |
| Macvlan devices can be added using the "ip" command from the | |
| iproute2 package starting with the iproute2-2.6.23 release: | |
| "ip link add link <real dev> [ address MAC ] [ NAME ] type macvlan" | |
| To compile this driver as a module, choose M here: the module | |
| will be called macvlan. | |
| config MACVTAP | |
| tristate "MAC-VLAN based tap driver" | |
| depends on MACVLAN | |
| help | |
| This adds a specialized tap character device driver that is based | |
| on the MAC-VLAN network interface, called macvtap. A macvtap device | |
| can be added in the same way as a macvlan device, using 'type | |
| macvlan', and then be accessed through the tap user space interface. | |
| To compile this driver as a module, choose M here: the module | |
| will be called macvtap. | |
| config VXLAN | |
| tristate "Virtual eXtensible Local Area Network (VXLAN)" | |
| depends on INET | |
| select NET_IP_TUNNEL | |
| ---help--- | |
| This allows one to create vxlan virtual interfaces that provide | |
| Layer 2 Networks over Layer 3 Networks. VXLAN is often used | |
| to tunnel virtual network infrastructure in virtualized environments. | |
| For more information see: | |
| http://tools.ietf.org/html/draft-mahalingam-dutt-dcops-vxlan-02 | |
| To compile this driver as a module, choose M here: the module | |
| will be called vxlan. | |
| config NETCONSOLE | |
| tristate "Network console logging support" | |
| ---help--- | |
| If you want to log kernel messages over the network, enable this. | |
| See <file:Documentation/networking/netconsole.txt> for details. | |
| config NETCONSOLE_DYNAMIC | |
| bool "Dynamic reconfiguration of logging targets" | |
| depends on NETCONSOLE && SYSFS && CONFIGFS_FS && \ | |
| !(NETCONSOLE=y && CONFIGFS_FS=m) | |
| help | |
| This option enables the ability to dynamically reconfigure target | |
| parameters (interface, IP addresses, port numbers, MAC addresses) | |
| at runtime through a userspace interface exported using configfs. | |
| See <file:Documentation/networking/netconsole.txt> for details. | |
| config NETPOLL | |
| def_bool NETCONSOLE | |
| config NETPOLL_TRAP | |
| bool "Netpoll traffic trapping" | |
| default n | |
| depends on NETPOLL | |
| config NET_POLL_CONTROLLER | |
| def_bool NETPOLL | |
| config NTB_NETDEV | |
| tristate "Virtual Ethernet over NTB" | |
| depends on NTB | |
| config RIONET | |
| tristate "RapidIO Ethernet over messaging driver support" | |
| depends on RAPIDIO | |
| config RIONET_TX_SIZE | |
| int "Number of outbound queue entries" | |
| depends on RIONET | |
| default "128" | |
| config RIONET_RX_SIZE | |
| int "Number of inbound queue entries" | |
| depends on RIONET | |
| default "128" | |
| config TUN | |
| tristate "Universal TUN/TAP device driver support" | |
| select CRC32 | |
| ---help--- | |
| TUN/TAP provides packet reception and transmission for user space | |
| programs. It can be viewed as a simple Point-to-Point or Ethernet | |
| device, which instead of receiving packets from a physical media, | |
| receives them from user space program and instead of sending packets | |
| via physical media writes them to the user space program. | |
| When a program opens /dev/net/tun, driver creates and registers | |
| corresponding net device tunX or tapX. After a program closed above | |
| devices, driver will automatically delete tunXX or tapXX device and | |
| all routes corresponding to it. | |
| Please read <file:Documentation/networking/tuntap.txt> for more | |
| information. | |
| To compile this driver as a module, choose M here: the module | |
| will be called tun. | |
| If you don't know what to use this for, you don't need it. | |
| config VETH | |
| tristate "Virtual ethernet pair device" | |
| ---help--- | |
| This device is a local ethernet tunnel. Devices are created in pairs. | |
| When one end receives the packet it appears on its pair and vice | |
| versa. | |
| config VIRTIO_NET | |
| tristate "Virtio network driver" | |
| depends on VIRTIO | |
| ---help--- | |
| This is the virtual network driver for virtio. It can be used with | |
| lguest or QEMU based VMMs (like KVM or Xen). Say Y or M. | |
| endif # NET_CORE | |
| config SUNGEM_PHY | |
| tristate | |
| source "drivers/net/arcnet/Kconfig" | |
| source "drivers/atm/Kconfig" | |
| source "drivers/net/caif/Kconfig" | |
| source "drivers/net/dsa/Kconfig" | |
| source "drivers/net/ethernet/Kconfig" | |
| source "drivers/net/fddi/Kconfig" | |
| source "drivers/net/hippi/Kconfig" | |
| config NET_SB1000 | |
| tristate "General Instruments Surfboard 1000" | |
| depends on PNP | |
| ---help--- | |
| This is a driver for the General Instrument (also known as | |
| NextLevel) SURFboard 1000 internal | |
| cable modem. This is an ISA card which is used by a number of cable | |
| TV companies to provide cable modem access. It's a one-way | |
| downstream-only cable modem, meaning that your upstream net link is | |
| provided by your regular phone modem. | |
| At present this driver only compiles as a module, so say M here if | |
| you have this card. The module will be called sb1000. Then read | |
| <file:Documentation/networking/README.sb1000> for information on how | |
| to use this module, as it needs special ppp scripts for establishing | |
| a connection. Further documentation and the necessary scripts can be | |
| found at: | |
| <http://www.jacksonville.net/~fventuri/> | |
| <http://home.adelphia.net/~siglercm/sb1000.html> | |
| <http://linuxpower.cx/~cable/> | |
| If you don't have this card, of course say N. | |
| source "drivers/net/phy/Kconfig" | |
| source "drivers/net/plip/Kconfig" | |
| source "drivers/net/ppp/Kconfig" | |
| source "drivers/net/slip/Kconfig" | |
| source "drivers/s390/net/Kconfig" | |
| source "drivers/net/usb/Kconfig" | |
| source "drivers/net/wireless/Kconfig" | |
| source "drivers/net/wimax/Kconfig" | |
| source "drivers/net/wan/Kconfig" | |
| source "drivers/net/ieee802154/Kconfig" | |
| config XEN_NETDEV_FRONTEND | |
| tristate "Xen network device frontend driver" | |
| depends on XEN | |
| select XEN_XENBUS_FRONTEND | |
| default y | |
| help | |
| This driver provides support for Xen paravirtual network | |
| devices exported by a Xen network driver domain (often | |
| domain 0). | |
| The corresponding Linux backend driver is enabled by the | |
| CONFIG_XEN_NETDEV_BACKEND option. | |
| If you are compiling a kernel for use as Xen guest, you | |
| should say Y here. To compile this driver as a module, chose | |
| M here: the module will be called xen-netfront. | |
| config XEN_NETDEV_BACKEND | |
| tristate "Xen backend network device" | |
| depends on XEN_BACKEND | |
| help | |
| This driver allows the kernel to act as a Xen network driver | |
| domain which exports paravirtual network devices to other | |
| Xen domains. These devices can be accessed by any operating | |
| system that implements a compatible front end. | |
| The corresponding Linux frontend driver is enabled by the | |
| CONFIG_XEN_NETDEV_FRONTEND configuration option. | |
| The backend driver presents a standard network device | |
| endpoint for each paravirtual network device to the driver | |
| domain network stack. These can then be bridged or routed | |
| etc in order to provide full network connectivity. | |
| If you are compiling a kernel to run in a Xen network driver | |
| domain (often this is domain 0) you should say Y here. To | |
| compile this driver as a module, chose M here: the module | |
| will be called xen-netback. | |
| config VMXNET3 | |
| tristate "VMware VMXNET3 ethernet driver" | |
| depends on PCI && INET | |
| help | |
| This driver supports VMware's vmxnet3 virtual ethernet NIC. | |
| To compile this driver as a module, choose M here: the | |
| module will be called vmxnet3. | |
| source "drivers/net/hyperv/Kconfig" | |
| endif # NETDEVICES |