| Kernel driver smsc47b397 | |
| ======================== | |
| Supported chips: | |
| * SMSC LPC47B397-NC | |
| * SMSC SCH5307-NS | |
| * SMSC SCH5317 | |
| Prefix: 'smsc47b397' | |
| Addresses scanned: none, address read from Super I/O config space | |
| Datasheet: In this file | |
| Authors: Mark M. Hoffman <mhoffman@lightlink.com> | |
| Utilitek Systems, Inc. | |
| November 23, 2004 | |
| The following specification describes the SMSC LPC47B397-NC[1] sensor chip | |
| (for which there is no public datasheet available). This document was | |
| provided by Craig Kelly (In-Store Broadcast Network) and edited/corrected | |
| by Mark M. Hoffman <mhoffman@lightlink.com>. | |
| [1] And SMSC SCH5307-NS and SCH5317, which have different device IDs but are | |
| otherwise compatible. | |
| * * * * * | |
| Methods for detecting the HP SIO and reading the thermal data on a dc7100. | |
| The thermal information on the dc7100 is contained in the SIO Hardware Monitor | |
| (HWM). The information is accessed through an index/data pair. The index/data | |
| pair is located at the HWM Base Address + 0 and the HWM Base Address + 1. The | |
| HWM Base address can be obtained from Logical Device 8, registers 0x60 (MSB) | |
| and 0x61 (LSB). Currently we are using 0x480 for the HWM Base Address and | |
| 0x480 and 0x481 for the index/data pair. | |
| Reading temperature information. | |
| The temperature information is located in the following registers: | |
| Temp1 0x25 (Currently, this reflects the CPU temp on all systems). | |
| Temp2 0x26 | |
| Temp3 0x27 | |
| Temp4 0x80 | |
| Programming Example | |
| The following is an example of how to read the HWM temperature registers: | |
| MOV DX,480H | |
| MOV AX,25H | |
| OUT DX,AL | |
| MOV DX,481H | |
| IN AL,DX | |
| AL contains the data in hex, the temperature in Celsius is the decimal | |
| equivalent. | |
| Ex: If AL contains 0x2A, the temperature is 42 degrees C. | |
| Reading tach information. | |
| The fan speed information is located in the following registers: | |
| LSB MSB | |
| Tach1 0x28 0x29 (Currently, this reflects the CPU | |
| fan speed on all systems). | |
| Tach2 0x2A 0x2B | |
| Tach3 0x2C 0x2D | |
| Tach4 0x2E 0x2F | |
| Important!!! | |
| Reading the tach LSB locks the tach MSB. | |
| The LSB Must be read first. | |
| How to convert the tach reading to RPM. | |
| The tach reading (TCount) is given by: (Tach MSB * 256) + (Tach LSB) | |
| The SIO counts the number of 90kHz (11.111us) pulses per revolution. | |
| RPM = 60/(TCount * 11.111us) | |
| Example: | |
| Reg 0x28 = 0x9B | |
| Reg 0x29 = 0x08 | |
| TCount = 0x89B = 2203 | |
| RPM = 60 / (2203 * 11.11111 E-6) = 2451 RPM | |
| Obtaining the SIO version. | |
| CONFIGURATION SEQUENCE | |
| To program the configuration registers, the following sequence must be followed: | |
| 1. Enter Configuration Mode | |
| 2. Configure the Configuration Registers | |
| 3. Exit Configuration Mode. | |
| Enter Configuration Mode | |
| To place the chip into the Configuration State The config key (0x55) is written | |
| to the CONFIG PORT (0x2E). | |
| Configuration Mode | |
| In configuration mode, the INDEX PORT is located at the CONFIG PORT address and | |
| the DATA PORT is at INDEX PORT address + 1. | |
| The desired configuration registers are accessed in two steps: | |
| a. Write the index of the Logical Device Number Configuration Register | |
| (i.e., 0x07) to the INDEX PORT and then write the number of the | |
| desired logical device to the DATA PORT. | |
| b. Write the address of the desired configuration register within the | |
| logical device to the INDEX PORT and then write or read the config- | |
| uration register through the DATA PORT. | |
| Note: If accessing the Global Configuration Registers, step (a) is not required. | |
| Exit Configuration Mode | |
| To exit the Configuration State the write 0xAA to the CONFIG PORT (0x2E). | |
| The chip returns to the RUN State. (This is important). | |
| Programming Example | |
| The following is an example of how to read the SIO Device ID located at 0x20 | |
| ; ENTER CONFIGURATION MODE | |
| MOV DX,02EH | |
| MOV AX,055H | |
| OUT DX,AL | |
| ; GLOBAL CONFIGURATION REGISTER | |
| MOV DX,02EH | |
| MOV AL,20H | |
| OUT DX,AL | |
| ; READ THE DATA | |
| MOV DX,02FH | |
| IN AL,DX | |
| ; EXIT CONFIGURATION MODE | |
| MOV DX,02EH | |
| MOV AX,0AAH | |
| OUT DX,AL | |
| The registers of interest for identifying the SIO on the dc7100 are Device ID | |
| (0x20) and Device Rev (0x21). | |
| The Device ID will read 0x6F (0x81 for SCH5307-NS, and 0x85 for SCH5317) | |
| The Device Rev currently reads 0x01 | |
| Obtaining the HWM Base Address. | |
| The following is an example of how to read the HWM Base Address located in | |
| Logical Device 8. | |
| ; ENTER CONFIGURATION MODE | |
| MOV DX,02EH | |
| MOV AX,055H | |
| OUT DX,AL | |
| ; CONFIGURE REGISTER CRE0, | |
| ; LOGICAL DEVICE 8 | |
| MOV DX,02EH | |
| MOV AL,07H | |
| OUT DX,AL ;Point to LD# Config Reg | |
| MOV DX,02FH | |
| MOV AL, 08H | |
| OUT DX,AL;Point to Logical Device 8 | |
| ; | |
| MOV DX,02EH | |
| MOV AL,60H | |
| OUT DX,AL ; Point to HWM Base Addr MSB | |
| MOV DX,02FH | |
| IN AL,DX ; Get MSB of HWM Base Addr | |
| ; EXIT CONFIGURATION MODE | |
| MOV DX,02EH | |
| MOV AX,0AAH | |
| OUT DX,AL |