| #!/usr/bin/python | |
| from __future__ import absolute_import, print_function, unicode_literals | |
| ''' | |
| Heart Rate Monitor test script | |
| ''' | |
| from optparse import OptionParser, make_option | |
| import sys | |
| import dbus | |
| import dbus.service | |
| import dbus.mainloop.glib | |
| try: | |
| from gi.repository import GObject | |
| except ImportError: | |
| import gobject as GObject | |
| import bluezutils | |
| BUS_NAME = 'org.bluez' | |
| HEARTRATE_MANAGER_INTERFACE = 'org.bluez.HeartRateManager1' | |
| HEARTRATE_WATCHER_INTERFACE = 'org.bluez.HeartRateWatcher1' | |
| HEARTRATE_INTERFACE = 'org.bluez.HeartRate1' | |
| class Watcher(dbus.service.Object): | |
| @dbus.service.method(HEARTRATE_WATCHER_INTERFACE, | |
| in_signature="oa{sv}", out_signature="") | |
| def MeasurementReceived(self, device, measure): | |
| print("Measurement received from %s" % device) | |
| print("Value: ", measure["Value"]) | |
| if "Energy" in measure: | |
| print("Energy: ", measure["Energy"]) | |
| if "Contact" in measure: | |
| print("Contact: ", measure["Contact"]) | |
| if "Interval" in measure: | |
| for i in measure["Interval"]: | |
| print("Interval: ", i) | |
| if __name__ == "__main__": | |
| dbus.mainloop.glib.DBusGMainLoop(set_as_default=True) | |
| bus = dbus.SystemBus() | |
| option_list = [ | |
| make_option("-i", "--adapter", action="store", | |
| type="string", dest="adapter"), | |
| make_option("-b", "--device", action="store", | |
| type="string", dest="address"), | |
| ] | |
| parser = OptionParser(option_list=option_list) | |
| (options, args) = parser.parse_args() | |
| if not options.address: | |
| print("Usage: %s [-i <adapter>] -b <bdaddr> [cmd]" % (sys.argv[0])) | |
| print("Possible commands:") | |
| print("\tReset") | |
| sys.exit(1) | |
| managed_objects = bluezutils.get_managed_objects() | |
| adapter = bluezutils.find_adapter_in_objects(managed_objects, | |
| options.adapter) | |
| adapter_path = adapter.object_path | |
| heartrateManager = dbus.Interface(bus.get_object(BUS_NAME, | |
| adapter_path), HEARTRATE_MANAGER_INTERFACE) | |
| path = "/test/watcher" | |
| heartrateManager.RegisterWatcher(path) | |
| device = bluezutils.find_device_in_objects(managed_objects, | |
| options.address, | |
| options.adapter) | |
| device_path = device.object_path | |
| heartrate = dbus.Interface(bus.get_object(BUS_NAME, device_path), | |
| HEARTRATE_INTERFACE) | |
| watcher = Watcher(bus, path) | |
| dev_prop = dbus.Interface(bus.get_object(BUS_NAME, device_path), | |
| "org.freedesktop.DBus.Properties") | |
| properties = dev_prop.GetAll(HEARTRATE_INTERFACE) | |
| if "Location" in properties: | |
| print("Sensor location: %s" % properties["Location"]) | |
| else: | |
| print("Sensor location is not supported") | |
| if len(args) > 0: | |
| if args[0] == "Reset": | |
| reset_sup = properties["ResetSupported"] | |
| if reset_sup: | |
| heartrate.Reset() | |
| else: | |
| print("Reset not supported") | |
| sys.exit(1) | |
| else: | |
| print("unknown command") | |
| sys.exit(1) | |
| mainloop = GObject.MainLoop() | |
| mainloop.run() |