 |  *  Copyright (C) 2015 Samsung Electronics | 
 |  *  Przemyslaw Marczak  <p.marczak@samsung.com> | 
 |  * | 
 |  * SPDX-License-Identifier:	GPL-2.0+ | 
 |  */ | 
 |  | 
 | #ifndef _SANDBOX_PMIC_H_ | 
 | #define  _SANDBOX_PMIC_H_ | 
 |  | 
 | #define SANDBOX_LDO_DRIVER		"sandbox_ldo" | 
 | #define SANDBOX_OF_LDO_PREFIX		"ldo" | 
 | #define SANDBOX_BUCK_DRIVER		"sandbox_buck" | 
 | #define SANDBOX_OF_BUCK_PREFIX		"buck" | 
 |  | 
 | #define SANDBOX_BUCK_COUNT	2 | 
 | #define SANDBOX_LDO_COUNT	2 | 
 | /* | 
 |  * Sandbox PMIC registers: | 
 |  * We have only 12 significant registers, but we alloc 16 for padding. | 
 |  */ | 
 | enum { | 
 | 	SANDBOX_PMIC_REG_BUCK1_UV = 0, | 
 | 	SANDBOX_PMIC_REG_BUCK1_UA, | 
 | 	SANDBOX_PMIC_REG_BUCK1_OM, | 
 |  | 
 | 	SANDBOX_PMIC_REG_BUCK2_UV, | 
 | 	SANDBOX_PMIC_REG_BUCK2_UA, | 
 | 	SANDBOX_PMIC_REG_BUCK2_OM, | 
 |  | 
 | 	SANDBOX_PMIC_REG_LDO_OFFSET, | 
 | 	SANDBOX_PMIC_REG_LDO1_UV = SANDBOX_PMIC_REG_LDO_OFFSET, | 
 | 	SANDBOX_PMIC_REG_LDO1_UA, | 
 | 	SANDBOX_PMIC_REG_LDO1_OM, | 
 |  | 
 | 	SANDBOX_PMIC_REG_LDO2_UV, | 
 | 	SANDBOX_PMIC_REG_LDO2_UA, | 
 | 	SANDBOX_PMIC_REG_LDO2_OM, | 
 |  | 
 | 	SANDBOX_PMIC_REG_COUNT = 16, | 
 | }; | 
 |  | 
 | /* Register offset for output: micro Volts, micro Amps, Operation Mode */ | 
 | enum { | 
 | 	OUT_REG_UV = 0, | 
 | 	OUT_REG_UA, | 
 | 	OUT_REG_OM, | 
 | 	OUT_REG_COUNT, | 
 | }; | 
 |  | 
 | /* Buck operation modes */ | 
 | enum { | 
 | 	BUCK_OM_OFF = 0, | 
 | 	BUCK_OM_ON, | 
 | 	BUCK_OM_PWM, | 
 | 	BUCK_OM_COUNT, | 
 | }; | 
 |  | 
 | /* Ldo operation modes */ | 
 | enum { | 
 | 	LDO_OM_OFF = 0, | 
 | 	LDO_OM_ON, | 
 | 	LDO_OM_SLEEP, | 
 | 	LDO_OM_STANDBY, | 
 | 	LDO_OM_COUNT, | 
 | }; | 
 |  | 
 | /* BUCK1 Voltage: min: 0.8V, step: 25mV, max 2.4V */ | 
 | #define OUT_BUCK1_UV_MIN	800000 | 
 | #define OUT_BUCK1_UV_MAX	2400000 | 
 | #define OUT_BUCK1_UV_STEP	25000 | 
 |  | 
 | /* BUCK1 Amperage: min: 150mA, step: 25mA, max: 250mA */ | 
 | #define OUT_BUCK1_UA_MIN	150000 | 
 | #define OUT_BUCK1_UA_MAX	250000 | 
 | #define OUT_BUCK1_UA_STEP	25000 | 
 |  | 
 | /* BUCK2 Voltage: min: 0.75V, step: 50mV, max 3.95V */ | 
 | #define OUT_BUCK2_UV_MIN	750000 | 
 | #define OUT_BUCK2_UV_MAX	3950000 | 
 | #define OUT_BUCK2_UV_STEP	50000 | 
 |  | 
 | /* LDO1 Voltage: min: 0.8V, step: 25mV, max 2.4V */ | 
 | #define OUT_LDO1_UV_MIN		800000 | 
 | #define OUT_LDO1_UV_MAX		2400000 | 
 | #define OUT_LDO1_UV_STEP	25000 | 
 |  | 
 | /* LDO1 Amperage: min: 100mA, step: 50mA, max: 200mA */ | 
 | #define OUT_LDO1_UA_MIN		100000 | 
 | #define OUT_LDO1_UA_MAX		200000 | 
 | #define OUT_LDO1_UA_STEP	50000 | 
 |  | 
 | /* LDO2 Voltage: min: 0.75V, step: 50mV, max 3.95V */ | 
 | #define OUT_LDO2_UV_MIN		750000 | 
 | #define OUT_LDO2_UV_MAX		3950000 | 
 | #define OUT_LDO2_UV_STEP	50000 | 
 |  | 
 | /* register <-> value conversion */ | 
 | #define REG2VAL(min, step, reg)		((min) + ((step) * (reg))) | 
 | #define VAL2REG(min, step, val)		(((val) - (min)) / (step)) | 
 |  | 
 | /* Operation mode id -> register value conversion */ | 
 | #define OM2REG(x)			(x) | 
 |  | 
 | /* Test data for: test/dm/power.c */ | 
 |  | 
 | /* BUCK names */ | 
 | #define SANDBOX_BUCK1_DEVNAME	"buck1" | 
 | #define SANDBOX_BUCK1_PLATNAME	"SUPPLY_1.2V" | 
 | #define SANDBOX_BUCK2_DEVNAME	"buck2" | 
 | #define SANDBOX_BUCK2_PLATNAME	"SUPPLY_3.3V" | 
 | /* LDO names */ | 
 | #define SANDBOX_LDO1_DEVNAME	"ldo1" | 
 | #define SANDBOX_LDO1_PLATNAME	"VDD_EMMC_1.8V" | 
 | #define SANDBOX_LDO2_DEVNAME	"ldo2" | 
 | #define SANDBOX_LDO2_PLATNAME	"VDD_LCD_3.3V" | 
 |  | 
 | /* | 
 |  * Expected regulators setup after call of: | 
 |  * - regulator_autoset_by_name() | 
 |  * - regulator_list_autoset() | 
 |  */ | 
 |  | 
 | /* BUCK1: for testing regulator_autoset_by_name() */ | 
 | #define SANDBOX_BUCK1_AUTOSET_EXPECTED_UV	1200000 | 
 | #define SANDBOX_BUCK1_AUTOSET_EXPECTED_UA	200000 | 
 | #define SANDBOX_BUCK1_AUTOSET_EXPECTED_ENABLE	true | 
 |  | 
 | /* BUCK2: for testing sandbox ADC's supply */ | 
 | #define SANDBOX_BUCK2_INITIAL_EXPECTED_UV	3000000 | 
 | #define SANDBOX_BUCK2_SET_UV			3300000 | 
 |  | 
 | /* LDO1/2 for testing regulator_list_autoset() */ | 
 | #define SANDBOX_LDO1_AUTOSET_EXPECTED_UV	1800000 | 
 | #define SANDBOX_LDO1_AUTOSET_EXPECTED_UA	100000 | 
 | #define SANDBOX_LDO1_AUTOSET_EXPECTED_ENABLE	true | 
 |  | 
 | #define SANDBOX_LDO2_AUTOSET_EXPECTED_UV	3000000 | 
 | #define SANDBOX_LDO2_AUTOSET_EXPECTED_UA	-ENOSYS | 
 | #define SANDBOX_LDO2_AUTOSET_EXPECTED_ENABLE	false | 
 |  | 
 | #endif |